Specifically dedicated to electric
vehicle charging stations
Specific for the EVC sector thanks to the following characteristics:
- Extended ambient temperature ranges up to 70°C
- MID certification in observance of legal metrology and commercial transaction requirement
- Integrated RS485 communications port running the Modbus RTU protocol.
Specifically dedicated to electric vehicle charging stations
DMED341MID7E… are specific for the EVC sector thanks to the following characteristics:
- Extended ambient temperature ranges up to 70°C
- MID certification in observance of legal metrology and commercial transaction requirement
- Integrated RS485 communications port running the Modbus RTU protocol.
Specifically dedicated to
electric vehicle charging stations
DMED341MID7E… are specific for the EVC sector thanks to the following characteristics:
- Extended ambient temperature ranges up to 70°C
- MID certification in observance of legal metrology and commercial transaction requirement
- Integrated RS485 communications port running the Modbus RTU protocol.
Compliant with German Eichrecht
calibration law
In particular, the DMED341MID7E… are also conforming with the requirements of:
VDE-AR-E 2418-3-100, 2020 edition, the standard used by charging station vendors to comply with the German calibration law (Eichrecht):
- MessEG (Mess und Eichgesetz)
- MessEV (Mess und Eichverordnung).
Compliant with German Eichrecht calibration law
In particular, the DMED341MID7E… are also conforming with the requirements of:
VDE-AR-E 2418-3-100, 2020 edition, the standard used by charging station vendors to comply with the German calibration law (Eichrecht):
- MessEG (Mess und Eichgesetz)
- MessEV (Mess und Eichverordnung).
Compliant with German Eichrecht
calibration law
In particular, the DMED341MID7E… are also conforming with the requirements of:
VDE-AR-E 2418-3-100, 2020 edition, the standard used by charging station vendors to comply with the German calibration law (Eichrecht):
- MessEG (Mess und Eichgesetz)
- MessEV (Mess und Eichverordnung).
DMED301MID7 – Main characteristics
- Measurements: energy, voltage, current
- Operating temperature: -25…+70°C
- Sealable terminal covers
- Metrological LED
- Backlit display
- Integrated RS485 communications port
- 4 module dimensions with DIN rail mounting
- Approval with module B + D (MID)
- EN50470-1
- EN50470-3 (class B) for accuracy
DMED341MID7E… – Main characteristics
- Measurements: energy, voltage, current
- Operating temperature: -25…+70°C
- Sealable terminal covers
- Metrological LED
- Backlit display
- Integrated RS485 communications port
- 4 module dimensions with DIN rail mounting
- Approval with module B + D (MID and MIR)
- IEC62052-31 for safety
- IEC62052-11 (general requirements)
- EN50470-3 (class B) for accuracy
- VDE-AR-E 2418-3-100 (German market, Eichrecht).
- Prepared for the transparency software from SAFE
In addiction DMED341MID7ER:
- MID version also for reverse/exported energy
DMED341MID7E… – Main characteristics
- Measurements: energy, voltage, current
- Operating temperature: -25…+70°C
- Sealable terminal covers
- Metrological LED
- Backlit display
- Integrated RS485 communications port
- 4 module dimensions with DIN rail mounting
- Approval with module B + D (MID and MIR)
- IEC62052-31 for safety
- IEC62052-11 (general requirements)
- EN50470-3 (class B) for accuracy
- VDE-AR-E 2418-3-100 (German market, Eichrecht).
- Prepared for the transparency software from SAFE
In addiction DMED341MID7ER:
- MID version also for reverse/exported energy
Model | DMED301MID7 | DMED341MID7E | DMED341MID7ER |
I Max | 80A | 80A | 80A |
Eichrecht | – | • | • |
MID version -25…+70°C | • | • | • |
MID version -25…+70°C also for reverse/exported energy | – | – | • |
Programmable output (pulses/thresholds) | – | • | • |
Built-in Modbus-RTU (RS485) | • | • | • |